EN 61000-4-2 electrostatic discharge (ESD) | 4 kV contact discharge, 8 kV air discharge |
EN 61000-4-3 electromagnetic field | 10 V/m (80-1000 MHz), 3 V/m (1.4-2 GHz), 1 V/m (2-2.7 GHz) |
EN 61000-4-4 fast transients (burst) | 2 kV power line, 1 kV data line |
EN 61000-4-5 surge voltage | power line: 0.5 kV (line/earth), 0.5 kV (line/line) |
EN 61000-4-6 conducted immunity | 10 V (150 kHz-80 MHz) |