Type |
SSR40-6TX/2SFP (Product code: SPIDER-SL-40-06T1O6O699SY9HHHH ) |
Description |
Unmanaged, Industrial ETHERNET Rail Switch, fanless design, store
and forward switching mode , Full Gigabit Ethernet |
Part Number |
942335015 |
Port type and quantity |
6 x 10/100/1000BASE-T, TP cable, RJ45 sockets, auto-crossing,
auto-negotiation, auto-polarity , 2 x 100/1000MBit/s SFP |
More
Interfaces
|
Power supply/signaling contact |
1 x plug-in terminal block, 3-pin |
Network
size - length of cable
|
Twisted pair (TP) |
0 - 100 m |
Single mode fiber (SM) 9/125 µm |
0 - 20 km, 0 - 11 dB Link Budget (with M-SFP-LX/LC) |
Multimode fiber (MM) 50/125 µm |
0 - 550m, 0 - 7,5 dB link budget (with M-SFP-SX/LC) |
Multimode fiber (MM) 62.5/125 µm |
0 - 275 m, 0 - 7,5 dB Link Budget at 850 nm (with M-SFP-SX/LC) |
Network
size - cascadibility
|
Line - / star topology |
any |
Power
requirements
|
Current consumption at 24 V DC |
Max. 555 mA |
Operating Voltage |
12/24 V DC (9.6 - 32 V DC) |
Power consumption |
Max. 13.3 W |
Power output in BTU (IT)/h |
45.4 |
Diagnostics
features
|
Diagnostic functions |
LEDs (power, link status, data, data rate) |
Ambient
conditions
|
MTBF |
1.088.487 h (Telcordia) |
MTBF (Telecordia SR-332 Issue 3) @ 25°C |
4 732 636 h |
Operating temperature |
0-+50 °C |
Storage/transport temperature |
-40-+70 °C |
Relative humidity (non-condensing) |
10 - 95 % |
Mechanical
construction
|
Dimensions (WxHxD) |
45 x 110 x 88 mm (w/o terminal block) |
Weight |
250 g |
Mounting |
DIN rail |
Protection class |
IP30 plastic |
Mechanical
stability
|
IEC 60068-2-6 vibration |
3.5 mm, 5–8.4 Hz, 10 cycles, 1 octave/min 1 g, 8.4–150 Hz, 10
cycles, 1 octave/min |
IEC 60068-2-27 shock |
15 g, 11 ms duration, 18 shocks |
EMC
interference immunity
|
EN 61000-4-2 electrostatic discharge (ESD) |
4 kV contact discharge, 8 kV air discharge |
EN 61000-4-3 electromagnetic field |
10V/m (80 – 3000 MHz) |
EN 61000-4-4 fast transients (burst) |
2kV power line; 4kV data line (SL-40-08T only 2kV data line) |
EN 61000-4-5 surge voltage |
power line: 2kV (line/earth), 1kV (line/line); 1kV data line |
EN 61000-4-6 Conducted Immunity |
10V (150 kHz - 80 MHz) |
EMC
emitted immunity
|
EN 55022 |
EN 55032 Class A |
FCC CFR47 Part 15 |
FCC 47CFR Part 15, Class A |
Approvals
|
|
Basis Standard |
CE, FCC, EN61131 |
Safety of industrial control equipment |
cUL 61010-1/61010-2-201 |
Reliability
|
|
Guarantee |
60 months (please refer to the terms of guarantee for detailed
information) |
Scope
of delivery and accessories
|
Accessories |
Rail Power Supply RPS 30/80 EEC/120 EEC (CC), Wall mounting plate
for DIN rail mounting (width 40/70 mm) |
Scope of delivery |
Device, terminal block, safety instruction
|