Chalmit Protecta III Fluorecent 2x18W EM PRGE/218/BI/EM/M25

Chalmit Protecta III Fluorecent 2x18W EM

PRGE/218/BI/EM/M25

Varenr: PRGE/218/BI/EM-2
Alt. varenr: 3348947

Protecta III (PRGE - Emergency)

 

by Chalmit Lighting 

Utilising the same reliable design of the standard Protecta III, the emergency version also features intelligent battery and lamp management technology. The luminaire is capable of self-commissioning and routine self-testing to ensure safe and dependable emergency operation. A high emergency output version is also available that increases the lumen output in emergency mode.

  • Ability to detect and indicate impending end of emergency lamp life before actual failure.
  • Battery management, monitoring and automatic self-test.
  • Emergency inhibition and mains power off re-start.
  • Automatic lamp de-energisation on opening.
  • DTS-01 deluge tested.
  • Vibration tested to comply with Lloyds/DNV.
  • End of life (EOL) protection to IEC 60079-7.

 

Type of protection

Ex e mb q (Increased safety Encapsulation Powder filling)

ATEX Classification

Group II Category 2 GD

Area Classification

Zone 1 and 21 areas to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079-14

Certificate

EC Type Examination Certificate Baseefa04ATEX0220

Coding

EX II 2 GD Ex e mb q IIC T4 Tamb 55°C

Enclosure

GRP body with polycarbonate cover and brass suspension points

Reflector/Geartray

White polyester painted zinc coated steel

Entry

4 x M20 cable entries, 2 at each end

Termination

Quick release mains terminals - 4 core 4mm² max. conductor with looping and 16A rating through wiring. (6mm² terminations available - /SC option)

Installation

Two M8 tapped brass inserts located on rear of body

Control Gear

High Frequency

Relamping

Quick release diffuser clamp and hinged cover

Lampholder

G13 (Bi-pin)

Burning Position

Universal

Ingress Protection

IP66/67 to EN 60529

Electrical Supply

220V - 254V 50/60Hz

Battery

Internal Ni-Cd (6V)

Duration

90 minutes to EN 60598-2-22

Emergency Output

50% of one lamp (18W)

25% of one lamp (36W)




Std. Cat No.

Wattage

Lamp

TClass

T°C (Dust)

Ambient °C

Weight

PRGE/218/BI/EM

2x18W

T8

T4

85

-20 to +55

7.4kg

PRGE/236/BI/EM

2x36W

T8

T4

85

-20 to +55

10.9kg

PRGE/218/MO/EM

2x18W

T8

T4

85

-20 to +55

7.4kg

PRGE/236/MO/EM

2x36W

T8

T4

85

-20 to +55

10.9kg

MO – Mono-pin (fa6 Cap) Lamps. Mono-pin Coding: Ex d e mb q IIC.

 




Options – Suffix to catalogue No.

/120

Specific voltage (110/130)

/M25

M25 cable entries

/SC

Screwed connection terminal block (up to 6mm² conductors)

/SB

Stainless steel mounting bush

/3P

3 phase termination facility (Not available if looping required)

/LBE

Looping both ends

/HEO

High emergency output - 45% (36W only)

/3H

3 hour battery duration*

/RI

Remote emergency inhibition facility (External switch ordered separately)

/SE

Spigot entry