Greyhound GMM40 Module 8xSFP gigabit GMM40-OOOOOOOOCV9HHS

Greyhound GMM40 Module 8xSFP gigabit

GMM40-OOOOOOOOCV9HHS

Varenr: GMM40-OOOOOOOOCV9HHS
Product description
DescriptionGREYHOUND1042 Gigabit Ethernet media module
Port type and quantity8 ports FE/GE ; 2x FE/GE SFP slot ; 2x FE/GE SFP slot ; 2x FE/GE SFP slot ; 2x FE/GE SFP slot
Network size - length of cable
Single mode fiber (SM) 9/125 µmport 1 and 3: see SFP modules; port 5 and 7: see SFP modules; port 2 and 4: see SFP modules; port 6 and 8: see SFP modules;
Single mode fiber (LH) 9/125 µm (long haul transceiver)port 1 and 3: see SFP modules; port 5 and 7: see SFP modules; port 2 and 4: see SFP modules; port 6 and 8: see SFP modules;
Multimode fiber (MM) 50/125 µmport 1 and 3: see SFP modules; port 5 and 7: see SFP modules; port 2 and 4: see SFP modules; port 6 and 8: see SFP modules;
Multimode fiber (MM) 62.5/125 µmport 1 and 3: see SFP modules; port 5 and 7: see SFP modules; port 2 and 4: see SFP modules; port 6 and 8: see SFP modules;
Power requirements
Operating Voltagevia switch
Power consumption7.5 W
Power output in BTU (IT)/h26
Ambient conditions
MTBF (Telecordia SR-332 Issue 3) @ 25°C33 626 288 h
Operating temperature0-+60 °C
Storage/transport temperature-40-+70 °C
Relative humidity (non-condensing)5-95 %
Protective paint on PCBYes (conformal coating)
Mechanical construction
Weight650 g
Mechanical stability
IEC 60068-2-6 vibration1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)8 kV contact discharge, 15 kV air discharge
EN 61000-4-3 electromagnetic field35 V/m (80-2700 MHz); 1 kHz, 80% AM
EN 61000-4-4 fast transients (burst)4 kV power line, 4 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line); data line: 1 kV; IEEE1613: power line 5kV (line/earth)
EN 61000-4-6 Conducted Immunity3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
EN 61000-4-16 mains frequency voltage30 V, 50 Hz continous; 300 V, 50 Hz 1 s
EMC emitted immunity
EN 55032EN 55032 Class A
Approvals
Safety of industrial control equipmentEN61131, EN60950
SubstationIEC61850, IEEE1613
Reliability
Guarantee60 months (please refer to the terms of guarantee for detailed information)
Scope of delivery and accessories
Scope of deliveryDevice, General safety instructions