OpenRail RS20 8xTX-RJ -40-70°C 9,6-60VDC Enhanced, GL approved

OpenRail RS20 8xTX-RJ

-40-70°C 9,6-60VDC Enhanced, GL approved

Varenr: RS20-0800T1T1TDHE

Product description

Description8 port Fast-Ethernet-Switch, managed, software Layer 2 Enhanced, for DIN rail store-and-forward-switching, fanless design
Port type and quantity8 ports in total; 1. uplink: 10/100BASE-TX, RJ45; 2. uplink: 10/100BASE-TX, RJ45; 6 x standard 10/100 BASE TX, RJ45
TypeRS20-0800T1T1TDHEHH09.0.
Order No.RS20-0800T1T1TDHEHH09.0.

More Interfaces

Power supply/signaling contact1 x plug-in terminal block, 6-pin
V.24 interface1 x RJ11 socket
USB interface1 x USB to connect the AutoConfiguration Adapter ACA21-USB

Network size - length of cable

Twisted pair (TP)0 m ... 100 m

Network size - cascadibility

Line - / star topologyany
Ring structure (HIPER-Ring) quantity switches50 (reconfiguration time < 0.3 sec.)

Power requirements

Operating voltage12/24/48 V DC (9,6-60) V and 24 V AC (18-30) V (redundant)
Current consumption at 24 V DC221 mA
Current consumption at 48 V DC111 mA
Power output in Btu (IT) h18.1

Software

ManagementTFTP; LLDP (802.1AB); V.24; HTTP; Traps; SNMP v1/v2/v3; Telnet
DiagnosticsManagement Address Conflict Detection; Address Relearn Detection; Signal Contact; Device Status Indication; LEDs; Syslog; Duplex Mismatch Detection; RMON (1,2,3,9); Port Mirroring 1:1; Port Mirroring 8:1; System Information; Self-Tests on Cold Start; SFP Management; Switch Dump
ConfigurationAutoConfiguration Adapter ACA11 Limited Support (RS20/30/40, MS20/30); Automatic Configuration Undo (roll-back); Configuration Fingerprint; BOOTP/DHCP Client with Auto-Configuration; AutoConfiguration Adapter ACA21/22 (USB); HiDiscovery; DHCP Relay with Option 82; Command Line Interface (CLI); Full-featured MIB Support; Web-based Management; Context-sensitive Help
SecurityIP-based Port Security; MAC-based Port Security; Access to Management restricted by VLAN; SNMP Logging; Local User Management
Redundancy functionsHIPER-Ring (Manager); HIPER-Ring (Ring Switch); Media Redundancy Protocol (MRP) (IEC62439-2); Redundant Network Coupling; RSTP 802.1D-2004 (IEC62439-1); RSTP Guards; RSTP over MRP
Industrial ProfilesEtherNet/IP Protocol; PROFINET IO Protocol
Time synchronisationSNTP server and client
MiscellaneousManual Cable Crossing
SwitchingDisable Learning (hub functionality); Independent VLAN Learning; Fast Aging; Static Unicast/Multicast Address Entries; QoS / Port Prioritization (802.1D/p); TOS/DSCP Prioritization; Egress Broadcast Limiter per Port; Flow Control (802.3X); VLAN (802.1Q); IGMP Snooping/Querier (v1/v2/v3)

Ambient conditions

Operating temperature-40 ºC ... 70 ºC
Storage/transport temperature-40 ºC ... 85 ºC
Relative humidity (non-condensing)10 % ... 95 %
MTBF63.4 years (MIL-HDBK-217F)
Protective paint on PCBNo

Mechanical construction

Dimensions (W x H x D)74 mm x 131 mm x 111 mm
MountingDIN Rail
Weight410 g
Protection classIP20

Mechanical stability

IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min

EMC interference immunity

EN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10 V/m (80-1000 MHz)
EN 61000-4-4 fast transients (burst)2 kV power line, 1 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)

EMC emitted immunity

FCC CFR47 Part 15FCC 47 CFR Part 15 Class A
EN 55022EN 55022 Class A

Approvals

Safety of industrial control equipmentcUL 508
Hazardous locationsISA 12.12.01 Class 1 Div. 2
Railway normEN50121-4
SubstationIEC 61850-3, IEEE 1613

Scope of delivery and accessories

Scope of deliveryDevice, terminal block, operating manual