Chalmit Acclaim Emergency LED ACLE/02L/LE/EM

Chalmit Acclaim Emergency LED

ACLE/02L/LE/EM

Varunummer: ACLE/02L/LE/EM

Acclaim (ACLE - Standard)

by Chalmit Lightning

Acclaim Recessible Luminaire is designed for use in offshore accommodation areas and control rooms where it provides recessible and escape lighting.
Manufactured from zinc coated sheet steel the luminaire is suitable for installation in fire resistant ceilings up to solas B15 rating. The mounting and cover details are
flexible to allow luminaires to be recessed into a variety of ceiling types.

  • Automatic lamp de-energisation on opening.
  • Battery management, monitoring and automatic self test.
  • Resistant to voltage fluctuations.
  • Local switching arrangement as standard.
  • Ingress protection to IP65.
  • B15 SOLAS fire rating - appropriate insulation is required over the luminaire.
  • Emergency inhibition and power off re-start.
  • End of life (EOL) protection to IEC 60079-7.

Product Details

General
ATEX Classification Group II Category 2 GD
Application Zone 1 and 21
Battery Type Internal 6V Ni-Cad Battery (4 Ah) - 18W; 6V (7Ah) - 36W.
Lamp Type T8 tubular fluorescent.
Light Distribution 90 minutes to EN60598-2-22.
Material White polyester painted zintec body and frame; Frame colour RAL 9010; Clear
polycarbonate diffuser.
Operating Temperature Range Celcius -20°C to +45°C
Style Linear
Type Linear
CSA File Number 1358946
Certified Listed
  • ATEX
  • NEC
  • IEC
Compliance IP65
Hazardous Rating(s) Zone 1 & 21
Industry Standard(s)
  • EN60079-10-1
  • EN60079-10-2
  • EN60079-14

Std. Cat No. Wattage Lamp TClass T° C(Dust) Ambient °C Weight
ACLE/218/BI 2x18W T8 T4 95 -20 to +45 9.5kg
ACLE/236/BI 2x36W T8 T4 95 -20 to +45 16.5kg
ACLE/218/BI/EM 2x18W T8 T4 95 -20 to +45 12.5kg
ACLE/236/BI/EM 2x36W T8 T4 95 -20 to +45 19.5kg

Options - Suffix to Catalogue No.
/120 Specific voltage (110/130) /PD Prismatic diffuser
/25 25mm cable entries /PC Solid plank ceiling
(Painted frame colour RAL 9016G)
/RI Remote emergency inhibition facility
(external switch ordered seperately)
/SC Screwed connection terminal block
(up to 6mm² conductors)
/3P 3 phase termination facility
(not available if through wiring required)
/NST High frequency - non self test ballast
/EL Extra live termination facility
(compatible with 4 core switched
emergency circuits)
/HEO High emergency output, 45% of one lamp
(36W version only)
/LG Low glare louvre /IEC Supplied with IECEx certification label
/3H 3 hour battery duration* /SSCS Brushed stainless steel cover (M300 ceiling only)
/SSC/PC Brushed stainless steel cover
(Solid ceiling only)
* 18W = 30% of one lamp, 36W = 25% of one lamp
Note: Ceiling type must be stated at time of enquiry/order