Spider Standard Line, 5xRJ45, 1xSFP SPIDER-SL-44-05T1O69999TY9HHHH

Spider Standard Line, 5xRJ45, 1xSFP

SPIDER-SL-44-05T1O69999TY9HHHH

Varunummer: 942274001
Product description
DescriptionUnmanaged, Industrial ETHERNET Rail Switch, fanless design, store and forward switching mode , Full Gigabit Ethernet with PoE+
Port type and quantity5 x 10/100/1000BASE-T, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity , thereof 4x PoE+ ports , 1 x 100/1000MBit/s SFP
More Interfaces
Power supply/signaling contact1 x plug-in terminal block, 4-pin
Network size - length of cable
Twisted pair (TP)0 - 100 m
Single mode fiber (SM) 9/125 µm0 - 20 km, 0 - 11 dB Link Budget (with M-SFP-LX/LC)
Multimode fiber (MM) 50/125 µm0 - 550m, 0 - 7,5 dB link budget (with M-SFP-SX/LC)
Multimode fiber (MM) 62.5/125 µm0 - 275 m, 0 - 7,5 dB Link Budget at 850 nm (with M-SFP-SX/LC)
Network size - cascadibility
Line - / star topologyany
Power requirements
Operating Voltage24/48 V DC (12 - 57 V DC / 12 - 18 V DC, derating output)
Power consumptionMax. 139.7 W with 120 W PoE output
Power output in BTU (IT)/hMax. 68
Diagnostics features
Diagnostic functionsLEDs (power, link status, data, data rate)
Ambient conditions
MTBF979.190 h (Telcordia)
Relative humidity (non-condensing)10 - 95 %
Mechanical construction
Dimensions (WxHxD)37 x 115 x 130 mm (w/o terminal block)
Weight710 g
MountingDIN rail
Protection classIP30 metal housing
Mechanical stability
IEC 60068-2-6 vibration3.5 mm, 5–8.4 Hz, 10 cycles, 1 octave/min 1 g, 8.4–150 Hz, 10 cycles, 1 octave/min
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)4 kV contact discharge, 8 kV air discharge 4 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10V/m (80 – 3000 MHz) 10V/m (80 – 3000 MHz)
EN 61000-4-4 fast transients (burst)2kV power line; 4kV data line (SL-40-08T only 2kV data line) 2kV power line; 4kV data line (SL-40-08T only 2kV data line)
EN 61000-4-5 surge voltagepower line: 2kV (line/earth), 1kV (line/line); 1kV data line power line: 2kV (line/earth), 1kV (line/line); 1kV data line
EN 61000-4-6 Conducted Immunity10V (150 kHz - 80 MHz) 10V (150 kHz - 80 MHz)
EMC emitted immunity
EN 55022EN 55032 Class A
FCC CFR47 Part 15FCC 47CFR Part 15, Class A
Approvals
Basis StandardCE, FCC, EN61131
Safety of industrial control equipmentcUL 61010-1/61010-2-201
Railway normEN50121-4
Reliability
Guarantee60 months (please refer to the terms of guarantee for detailed information)
Scope of delivery and accessories
AccessoriesRail Power Supply RPS 30/80 EEC/120 EEC (CC), Wall mounting plate for DIN rail mounting (width 40/70 mm)
Scope of deliveryDevice, terminal block, safety instruction
Further Instructions
Product Documentationhttps://www.doc.hirschmann.com/index.html
Certificateshttps://www.doc.hirschmann.com/certificates.html