GRM20 media module for Greyhound switch GRM20-NNNNNNNNSV9HHS

GRM20 media module for Greyhound switch

GRM20-NNNNNNNNSV9HHS

Varunummer: GRM20-NNNNNNNNSV9HHS
Product description
DescriptionGREYHOUND Fast Ethernet Media Module
Port type and quantity8 x ports in total ; 2 x FE MM, ST ; 2 x FE MM, ST ; 2 x FE MM, ST ; 2 x FE MM, ST
Network size - length of cable
Multimode fiber (MM) 50/125 µmport 1 and 3: 0 - 5000 m, 8 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km; port 5 and 7: 0 - 5000 m, 8 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km; port 2 and 4: 0 - 5000 m, 8 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km; port 6 and 8: 0 - 5000 m, 8 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km;
Multimode fiber (MM) 62.5/125 µmport 1 and 3: 0 - 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km; port 5 and 7: 0 - 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km; port 2 and 4: 0 - 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km; port 6 and 8: 0 - 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km;
Power requirements
Operating Voltagepower supply via GREYHOUND switch
Power consumption9 W
Power output in BTU (IT)/h31
Ambient conditions
Operating temperature0-+60 °C
Storage/transport temperature-40-+70 °C
Relative humidity (non-condensing)5-95 %
Mechanical construction
Weight520 g
Protection classIP30
Mechanical stability
IEC 60068-2-6 vibration1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)8 kV contact discharge, 15 kV air discharge
EN 61000-4-3 electromagnetic field35 V/m (80-2700 MHz); 1 kHz, 80% AM
EN 61000-4-4 fast transients (burst)4 kV power line, 4 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line); data line: 1 kV; IEEE1613: power line 5kV (line/earth)
EN 61000-4-6 Conducted Immunity3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
EN 61000-4-16 mains frequency voltage30 V, 50 Hz continous; 300 V, 50 Hz 1 s
EMC emitted immunity
EN 55022EN 55032 Class A
FCC CFR47 Part 15FCC 47CFR Part 15, Class A
Approvals
Basis StandardCE, FCC, EN61131
Safety of industrial control equipmentEN60950
SubstationIEC61850, IEEE1613
Scope of delivery and accessories
Scope of deliveryDevice, General safety instructions