OpenRail RSB20 8xTX-RJ 0-60°C 9,6-60VDC Basic

OpenRail RSB20 8xTX-RJ

0-60°C 9,6-60VDC Basic

Varunummer: RSB20-0800T1T1SAAB
Alt. varenr: 942 014-001

Product description

DescriptionEthernet/Fast Ethernet-Switch acc. to IEEE 802.3, compact, managed, Industrial switch for DIN Rail, Store-and-Forward-Switching, fanless design
Port type and quantity8 ports in total; 1. uplink: 10/100BASE-TX, RJ45; 2. uplink: 10/100BASE-TX, RJ45; 6 x standard 10/100 BASE TX, RJ45
TypeRSB20-0800T1T1SAABHH
Order No.942 014-001

More Interfaces

Power supply/signaling contact1 x plug-in terminal block, 6-pin
V.24 interface1 x RJ11 socket

Network size - length of cable

Twisted pair (TP)0 m ... 100 m

Network size - cascadibility

Line - / star topologyany
Ring structure (HIPER-Ring) quantity switches50 (reconfiguration time < 0.3 sec.)

Power requirements

Operating voltage24 V DC (18-32 V)
Current consumption at 24 V DC215 mA
Power output in Btu (IT) h18

Software

ManagementSerial interface, web-interface, SNMP V1/V2, HiVision file transfer SW HTTP/TFTP
DiagnosticsLEDs, Log-File, signal contact, RMON (statistic, history, alarms, events), port mirroring, topology discovery 802.1AB
ConfigurationComand Line Interface (CLI), BootP, DHCP, DHCP Option 82, HIDiscovery, auto-configurationadapter (ACA11)
SecuritySNMP V3 (no encryption)
Redundancy functionsHIPER-Ring (client and server), MRP (client and server), RSTP - IEEE802.1D-2004
FilterQoS 4 classes, port priorisation (IEEE 802.1D/p), multicast IGMP (Snooping and Querier, Fast Aging
Industrial ProfilesEtherNet/IP and PROFINET compatibel
Time synchronisationSNTP Client and Server, IEEE 1588 client
Flow controln/a
PresettingsStandard

Ambient conditions

Operating temperature0 ºC ... 60 ºC
Storage/transport temperature-40 ºC ... 70 ºC
Relative humidity (non-condensing)10 % ... 95 %
MTBFn/a
Protective paint on PCBNo

Mechanical construction

Dimensions (W x H x D)71 mm x 131 mm x 111 mm
MountingDIN Rail
Weight400 g
Protection classIP20

Mechanical stability

IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz-150 Hz, 10 cycles, 1 octave/min.

EMC interference immunity

EN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10 V/m (80-1000 MHz)
EN 61000-4-4 fast transients (burst)2 kV power line, 1 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
EN 61000-4-16 mains frequency voltagen/a

EMC emitted immunity

FCC CFR47 Part 15FCC 47 CFR Part 15 Class A
EN 55022EN 55022 Class A

Approvals

Safety of industrial control equipmentcUL 508
Hazardous locationsISA 12.12.01 Class 1 Div. 2 (pending)
Shipbuildingn/a
Railway normn/a
Substationn/a
Transportationn/a

Scope of delivery and accessories

Scope of deliveryDevice, terminal block, operating manual