The Ex-Handy 10 with Android operating system, is the ideal companion for innovative Industry 4.0 applications in hazardous areas. With IP68 and Gorilla® Glass you can operate the Ex-Handy 10 in the roughest of environments. With a 5-year product lifecycle and global Ex-certifications to meet all requirements, it provides a low risk investment to the user.
With customer-specific configurations and customizations, it also handles the most demanding of situations.
Technical
Data |
|
Operating
System |
Android™ 9 | Google Play |
Processor |
Qualcomm Snapdragon MSM8909
platform |
Memory |
RAM: 2 GB
Internal data memory: 16 GB
With external microSD up to 128 GB |
Display |
6,6 cm / (2,6")
capacitive multi-touch screen made of extreme shock and scratch resistant
Gorilla glass
Support of glove and wet mode
High Visibility in direct sunlight |
Ports |
Water-proof magnetic
USB 2.0 connector
3.5 mm jack connection with special ecom mounting solution |
Dimensions |
148 x 67 x 24 mm |
Weight |
Approx. 330 g |
Dedicated keys |
Programmable key /
Alarm / Power / Multifunction / Volume / Hardware buttons for Android
features |
Connectivity |
4G / LTE -standard (SIM unlocked
and free); Nano SIM |
WiFi
802.11 a/b/g/n/e/k/r/h; 2.4 Ghz and 5 Ghz support |
Bluetooth®
4.2 incl. BLE (Bluetooth Low Energy) |
GPS /
A-GPS / Glonass / Beidou |
NFC |
Camera |
8 MP rear camera with
auto focus (optional) and LED flash with torchlight function |
Power |
4400 mAh |
Frequency
bands |
Cellular frequency bands:
4G LTE FDD: B1, B2, B3, B4, B5, B7, B8, B11, B12, B13, B20, B21, B25, B26,
B28, B66, B71
4G LTE TDD: B38, B39, B40, B41 (2540 Mhz to 2640 Mhz)
3G UMTS: 850 / 900 / 1700 / 1900 / 2100 MHz
2G GSM: 850 / 900 / 1800 / 1900 MHz |
Protection |
IP68, MIL-STD-810G |
Ex® Certification
ATEX
II 2G Ex ib op is IIC T4 Gb IP64
II 2D Ex ib op is IIIC T120°C Db
Ambient temperature: -20 °C = Ta = +60 °C
IECEx
Ex ib op is IIC T4 Gb IP64
Ex ib op is IIIC T120°C Db
Ambient temperature: -20 °C = Ta = +60 °C