Pico TC-08 thermocouple data logger
Now with PicoLog Cloud®
Building on the proven design of PicoLog 6, PicoLog Cloud is a free upgrade that introduces many great new features that expand how your Pico data logger can be used.
PicoLog Cloud allows all current Pico data loggers and real-time scopes to capture data directly to our new free Cloud service, and can be shared via a link to any browser on a PC, phone or tablet, anywhere in the world. In addition, an API can be used that allows live capture data to be transferred from the Cloud to a 3rd party database or program.
A Pico Technology TC-08 PicoLog datalogger
- 8 channel thermocouple data logger
- Measures from –270 to +1820 °C (–454 to +3308 °F)
- High resolution and accuracy
- Expandable to 20 units / 160 channels
- Supports all popular thermocouple types
- Fast sampling rate — up to 10 measurements per second (including CJC)
- USB connected and powered
- PicoLog 6 for Windows, macOS and Linux data logging software included
- PicoSDK drivers for Windows, macOS and Linux included
Wide temperature range
The TC-08 thermocouple data logger is designed to measure a wide range of temperatures using any thermocouple that has a miniature thermocouple connector. Pico supply a wide range of suitable thermocouples.
All popular types of thermocouple are supported, allowing an effective temperature range of –270 to +1820 °C (the actual temperature range depends on the thermocouple being used).
The built in Cold Junction Compensation (CJC) circuit can also be used as a 9th channel to measure room temperature.
PicoLog 6 graph view showing temperature and pressure
Fast and accurate temperature data acquisition
With the TC-08 thermocouple data logger your temperature measurements can be made both fast and accurately.
The short conversion time of the TC-08 means up to 10 temperature measurements can be taken every second (cold junction compensation counts as an additional measurement), while the high (20-bit) resolution ensures that the TC-08 can detect minute changes in temperature. For popular Type K thermocouples the TC-08 can maintain a better than 0.025°C resolution over a –250 to +1370 °C range.
The optional Single-Channel Terminal Board plugs into a channel on the TC-08 and turns it into a 20-bit high resolution data logger. Screw terminals allow wires to be attached to the data logger without soldering. The four input ranges (±50 mV, ±500 mV, ±5 V and 4-20 mA) allow a wide range of other sensors and signals to be measured.